Hi everybody,
I am designing my PCB (OrCAD 16.6). When I place parts of a room I see below message:
Class: DRC ERROR CLASS Subclass: PACKAGE_BOTTOM Origin xy: (1068.00 178.00) Constraint: Package to Room Spacing Constraint Set: NONE Constraint Type: DESIGN Constraint value: 0 MIL Actual value: 65 MIL - - - - - - - - - - - - - - - - - - - - Element type: SHAPE Class: PACKAGE GEOMETRY Subclass: PLACE_BOUND_BOTTOM RefDes: R19 Room: FW_PW_ADC - - - - - - - - - - - - - - - - - - - - Element type: RECTANGLE Class: BOARD GEOMETRY Subclass: BOTH_ROOMS Room: not named Room type: HARD xy-lower xy-upper Rectangle Top: (1208.00 61.00)(93.00 61.00) Rectangle Bottom: (1208.00 585.00)(93.00 585.00) Height: 524.00 mils Width: 1115.00 mils Area: 0.584 (sq in)
I tried to find and fix it in CM (Constraint Manager). However, I only saw it in the DRC -> Spacing section which is Read-Only and doesn't change. Does anybody know how I can fix this issue?
Thanks in advance,
Hossein